Finite Different Method Demo Tutorial
Test the software with the following inputs (Navarro et al., 2012):
Spatial discretization: dx = 0.5 m;
Time discretization: dt = 1/8000 s;
Recording total time: T = 2.0 s;
Room dimension: 8.0 m x 8.0 m x 8.0 m;
Absorption Coefficient surface i: 1/6 ≈ 0.17;
Air absorption: 0.0 1/m;
Absorption term: A_{M};
Source On time: S = 1.0 s;
Source position coordinates: 4.0, 4.0, 4.0;
Receiver position coordinates: 2.0, 2.0, 2.0;
Test if the software provides the following results (Navarro et al., 2012):
Reverberation time (RT): 1.18 s;
Early Decay Time (RDT): 1.18 s;
Clarity (C_{80}): 2.08 dB;
Definition (D_{50}): 45.63 %
Centre Time (T_{s}): 85.33 ms